Shutting Down Control Hub
You can shut down
and then manually launch Control Hub
to apply changes to the Control Hub
configuration files.
Note: Any registered Data Collectors
that are running at the time of the Control Hub shutdown continue to run remote pipeline instances in Control Hub disconnected mode. The Data Collectors
maintain the offsets for the running pipelines and update Control Hub with the latest offsets as soon as they reconnect to Control Hub.
To shut down when Control Hub is started as a service,
use the required command for your operating system:
- For CentOS 6.x, Oracle Linux 6.x, Red Hat Enterprise Linux 6.x, or
Ubuntu 14.04, use:
service dpm stop
- For CentOS 7.x, Oracle Linux 7.x - 8.x, or Red Hat Enterprise Linux
7.x - 8.x,
use:
systemctl stop dpm
To shut down when Control Hub is started manually from
the tarball, use the Control Hub
process ID in the following command:
kill <process ID>